Performance

Due to the fact that these fires are made to measure, no performance information is available
Specification

Custom fires - Minimum and Maximum Dimensions

  Max Width Min Width Max Depth Min Depth* Min Depth  
NG 711mm (29") 229m (10") 381mm (16") 114mm (5") 140mm (6") NG
LPG 457mm (19") 229m (10") 279mm (12") 152mm (7") 165mm (7") LPG

* Denotes using detached BM valve option

Standard Control Knob Location: Front facing, 15mm proud of burner front and positioned off-centre on right hand side of burner, 100mm from centre line.
Where controls are supplied loose with mounting bracket, they must be located within 812mm (Natural Gas)/432mm (LPG) of the oxypilot.
Installation Requirements

The installation of your appliance must be undertaken by a competent person in accordance with the installation instructions and the regulations currently in force.  It is mandatory that all gas installers be CORGI registered.

The chimney must comply with the Building Regulations for Class 1 Appliances and must have a minimum 7" diameter and a minimum height of 10ft.  A faulty flue or chimney may result in smoke and fumes coming into the room.

It is recommended that a fireguard complying with BS6539 or BS6778 be fitted for the protection of young children, the elderly or infirm.